Fix the update documentation screen doesn't display the current status of "With Perf Mon" field.
1. Product versions:
- OS and Version: Windows
- TM1/PA Version: 11.8
- Pulse Version 6.1.2
3. Describe the bug
Due to locking caused by the Stats thread it is common to turn the "Performance Monitor" option under "Instance configuration" off. Should the cusommer require updated documentation (with stats) then
- switch performance monitor on in instance settings and save settings
- run documentation manually
- turn performance monitor off again in instance settings and save settings
This leads to confusion for users as although the documentation does run with the changes performance monitor setting. What is displayed on the "Update Documentation" screen in the "With Perf Mon" field is the old settings not what has just been saved. This leads the user to mistrust the system as it seems the change they just made has not been reflected.
4. To Reproduce
- Go to Administration > Instance Settings and select a particular instance
- Under Documentation either tick or untick the Performance Monitor checkbox (just reverse the previous value)
- Under Administration > Update Documentation observe that the "With Perf Mon" field does not reflect the updated value.
5. Expected behavior
Update Documentation screen must show current values for the With Perf Mon field.